Energy Audits, Energy Conservation Projects, Waste Heat Recovery On D.G.Sets / Ovens / Furnaces, Thermal Efficiency Verification, Furnace Oil Conversion Systems, Conversion Of Electrical Heating To Steam Heating, Conversion From Oil Firing To Solid Fuel Firing System, Biomass Briquettes, Solar Steam Generating Plants, Solar Steam Cooking System For Institutes / Hotels / Hostels, Steam And Hot Air Requirements For Industrial Use, Boiling And Frying In Food Processing Industries, Sterilization, Laundry And Incinerators For Hospital Use, Drying / Dying In Textile Industries For Vapour Absorption, Refrigeration And Central Air Conditioning, Solar Distilled Water Plants, Steam And Hot Air For Pharmaceutical Industries, All Types Of Heat Requirements For Any Purpose, Biogas Plants, Air Preheater Non IBR Boiler / Ovens / Furnaces, Air Preheater For Thermo-Pack Fuel Saving Devices For All Fuels, Furnace Oil Conversion System For Hot Mix Plant, F.O. Conversion System For Heat Treatment Furnace, Flux Maxiox Fuel Saving Devices, Flux Maxguard Water Treatment Devices, Thermic Fluid Heating Systems, Foundry Thermal Equipments ( Core Drying Ovens ), Waste Heat Recovery On Furnaces, Insulation Projects To Avoid Losses, F.O. Emulsification Systems, Furnace Oil Ring Main Circuit For Furnace Oil Firing Systems, Biomass Briquette Fired Thermic Fluid Heating Systems, Thermic Fluid Heating System, Foundry Thermal Equipment, Ladle Preheaters, Direct And Indirect Type Hot Air Generators, Heat Treatment Furnace, Core Drying Backing Ovens, Bio Medical Waste Incinerators, Industrial Burners, Hot Air Generators ( Direct / Indirect), Hot Water Generators, Heat Treatment Furnaces

Energy Audits, Energy Conservation Projects, Thermal Efficiency Measurements, Up gradation Schemes, Process Instrumentations, Biogas Plants, Furnace Oil Conversion Systems

 
          Our Activities & Products :
 
* Energy Audits
* Energy Conservation Projects
* Thermal Efficiency Measurement & Up gradation Schemes
* Waste Heat recovery Systems on D.G. Sets / Ovens / Furnaces
* Process Instrumentation For Energy Conservation
* Solar Steam Generating Plants for Industrial Applications
* Biogas Plants
* Core Drying (Continious / Batch) Type Ovens
* Heat Treatment Furnaces
* Foundry Thermal Equipments
* Laddle Preheaters
* Furnace Oil Conversion Systems
* Use Of Non Conventional Energy Resources
 
 
 
Waste Heat Recovery Systems on Furnace

Waste Heat Recovery Systems on Furnace
 
 
By using waste heat in exhaust gases from Furnaces. We Can generate steam, hot air

  • Product- Non IBR Steam Boiler.
  • Furnace Exhaust Gas Temperature - 250 Deg.C (Boiler Inlet Temperature)
  • Boiler Outlet Temperature - 150 Deg.C.
  • Steam Generation - 46 kg / hr.
  • Heat Recovery - 25000 kcal / hr.
  • Annual Savings - Rs. 8,64,825.00. (7000 working hours)
  • Pay Back Period - 8 months.
 
 
Waste Heat Recovery Systems on D.G. Set Exhausts ( Hot Water Generator )

Waste Heat Recovery Systems on D.G. Set Exhausts ( Hot Water Generator )

By using waste heat in exhaust gases
from D.G.Sets / Ovens. We Can generate steam, hot water, hot air

  • D.G.Set Capacity - 750 KVA. (2Nos).
  • Heat Recovery - 4,80,000 kcal / hr.
  • Water Inlet Temperature - 90 Deg.C.
  • Water Outlet Temperature - 105 Deg.C.
  • LPG Saving Per Hour - 43 kg / hr.
  • Cost Saving Per Year - Rs 19,35,000 / year.
    (D.G. running 5 / hr day x 300 days)
  • Pay Back Period - 7 months.
 
 
Air-Preheaters For Thermopack

Air-Preheaters For Thermopack
Air Preheaters for Steam Boiler, Thermic Fluid Heater, Furnace, Ovens.
 

  • Thermopack Capacity - 6,00,000 kcal / hr.
  • Stack Temperature Before Airpreheater - 250 Deg.C.
  • Stack Temperature After Airpreheater - 180 Deg.C
  • Combination Air Temperature - 120 Deg.C.
  • Efficiency Increased By - 5 %.
  • Annual Saving In F.O. Cost - 6,00,000 /-
  • Additional Benefits Of Airpreheater - Complete Combustion Clean Burner assembly Low Maintainance.
  • Pay Back Period - 12 months.