PRODUCTS |
|
|
Pump Control Panel |
|
|
|
|
|
|
|
We do the logic design as per users specific requirement and supply the Control Panel ready to work. It may even PLC based control. Required process measuring instruments are also supplied. |
|
|
|
Special features of Pump control panel :
* Over/Under Supply Voltage Protection
* Phase Reversal protection
* Over load/current protection for the pump Motor
* Dry run protection for the pump motor
* Auto trip off at set fault
* Audio visual alarm
* Driving current and supply voltage indication |
|
|
|
Additional/Special Alarm panel System/ PLC or Simple ON/OFF Panel. |
|
................................................................................................................................................................................................................. |
|
|
|
|
Portable Hay & Straw Moisture Meter |
|
|
|
|
|
|
|
A handy battery operated user friendly meter for measuring water content in Hay , Straw bales, Biomass and similar item at a glance.
APPLICATIONS
* TO DETECT MOISTURE RELATED MACHINERY ISSUES PRIOR TOOPERATION.
* HELPS BIOMASS PRODUCERS
* TO ENSURE THE RATE FOR BUYERS BECAUSE OF EXCESSIVE WATER CONTENT
FEATURES
* Fitted with 0.6 meter (23.62 in) stabbing insertion proble.
* Large, well-lit Graphical LCD display.
* Hold function.
* Automatic temperature compensation optimizes Accuracy.
* Built-in datalogger for 10,000 Values
* Supplied in custom-fitted wood carrying case.
SPECIFICATIONS
* Range - 8 -40 % water content (Resolution- 0.5 % )
Temperature: (-) 20 °C to 120 °C (Resolution- 0.1 oC)
* Display - Graphic LCD with backlight (128 x 64 pixel)
* Accuracy- +/- 2.5 % ( @23C <80%)
* Sensor : Conductance type
* Response -<30 sec for 80 % attenuation
* Operating environment : 32 °F to 104 °F (0° to 40 °C ) 0 C to 50 C,
* Range - 4 x Four 1.5 Volt AA Alkaline batteries
* Housing – High Impact Plastic IP40 (6" x 6" x 48" aprox with shipping box)
* Data logging - 10,000 moisture measurements plus date, batch & temperature
* Operational Area:- Safe Area |
|
|
|
* In view of betterment, the product specification are subject to change without notice. |
|
................................................................................................................................................................................................................. |
|
|
|
Oxygen Analyzer for Continuous Check… |
|
|
|
|
|
|
|
Oxygen analyzer uses HI Tech Sensor with user friendly operative feature for measuring oxygen concentration.
APPLICATIONS
* KEEP CONTROLING OXYGEN LEVEL IN AIR SEPERATION PLANTS.
* CHECKING CYLINDER GAS QUALITY.
* PHARMA & FOD INDUSTRIES.
* PURGE GAS MONITORING.
FEATURES
* Uses latest HI Tech sensor (Zirconia/Electrochemical).
* Supplied with sampling system.
* Measures up to 100 % for purity and also in PPM for Traces.
* Fast response time.
Ennovacion series oxygen analyser measures oxygen concentrations from percentage levels to a fractions of parts per million (ppm) in clean gases.
Packaged on a 19” rack mounting enclosure, it uses a zirconia oxygen sensor to provide accurate measurement with minimal interference from other gases. The unique cell and heater design gives very fast warm-up times, rapid response, and long sensor life. A wide choice of sampling options is provided to produce virtually ‘custom-built’ systems. A large multi-digit auto ranging LCD is used to display measured concentrations and the user adjustable parameters in configuration mode.
The standard sampling system is a simple needle valve and flow meter arrangement.
Standard options provide alternatives to cover a wide variety of applications.
MM Automation also supply a range of sample conditioning accessories to cater for most sample sources. |
|
|
|
SPECIFICATIONS |
|
|
|
Display |
: |
Multi-digit LCD, character height 12.7mm |
Range |
: |
0.1ppm to 100% oxygen,(as per application) |
Resolution |
: |
From 10% to 100%: 0.1% & .01% up to 9.99%.
From 0 to 5/50/500ppm: 0.01/0.1/01/10ppm |
Accuracy |
: |
100% to 100ppm: }2% of reading or better
99ppm to 10ppm: }1ppm
0.1ppm to 9/9ppm: }0.2ppm |
Stability |
: |
Better than 2% of reading or 0.5ppm/month, whichever is greater |
Sample flow |
: |
Between 100 and 300ml/min for optimum operation |
Response |
: |
Iin clean inert atmospheres % levels- less than 02s for 90% change Levels from 500 to 100ppm: less than 15s for 90% change. For lesser ,its higher. |
Sample |
: |
Inlet pressure 10mbar minimum/8bar maximum Temperature Ambient |
Sampling |
: |
Extra As per application |
Connection |
: |
located on back panel of unit. fitting suitable for 0.25inch/6mm outside diameter tube |
Output |
: |
Standard : 4 to 20mA |
Alarm outputs |
: |
2 alarms: each user-configurable to OFF, HIGH or LOW status |
Ambient temperature |
: |
50 °C maximum |
Power supply |
: |
Please specify option required from the following:
110/230V, 50 Hz at 80VA max |
Mounting |
: |
19” Rack-mounting enclosure 3U high and 270mm deep |
|
|
|
|
|
* In view of betterment, the product specification are subject to change without notice. |
|
|