Gas Detectors, Gas Analysers, Gas Analysis, Moisture Analyser

 

PRODUCTS
 
 

Pump Control Panel

   
 
Pump Control Panel Pump Control Panel
   
  We do the logic design as per users specific requirement and supply the Control Panel ready to work. It may even PLC based control. Required process measuring instruments are also supplied.
   
  Special features of Pump control panel :

* Over/Under Supply Voltage Protection
* Phase Reversal protection
* Over load/current protection for the pump Motor
* Dry run protection for the pump motor
* Auto trip off at set fault
* Audio visual alarm
* Driving current and supply voltage indication
   
  Additional/Special Alarm panel System/ PLC or Simple ON/OFF Panel.
  .................................................................................................................................................................................................................
 
 

Portable Hay & Straw Moisture Meter

   
 
Portable Hay & Straw Moisture Meter  
   
  A handy battery operated user friendly meter for measuring water content in Hay , Straw bales, Biomass and similar item at a glance.

APPLICATIONS

* TO DETECT MOISTURE RELATED MACHINERY ISSUES PRIOR TOOPERATION.
* HELPS BIOMASS PRODUCERS
* TO ENSURE THE RATE FOR BUYERS BECAUSE OF EXCESSIVE WATER CONTENT

FEATURES

* Fitted with 0.6 meter (23.62 in) stabbing insertion proble.
* Large, well-lit Graphical LCD display.
* Hold function.
* Automatic temperature compensation optimizes Accuracy.
* Built-in datalogger for 10,000 Values
* Supplied in custom-fitted wood carrying case.

SPECIFICATIONS

* Range - 8 -40 % water content (Resolution- 0.5 % )
                Temperature: (-) 20 °C to 120 °C (Resolution- 0.1 oC)
* Display - Graphic LCD with backlight (128 x 64 pixel)
* Accuracy- +/- 2.5 % ( @23C <80%)
* Sensor : Conductance type
* Response -<30 sec for 80 % attenuation
* Operating environment : 32 °F to 104 °F (0° to 40 °C ) 0 C to 50 C,
* Range - 4 x Four 1.5 Volt AA Alkaline batteries
* Housing – High Impact Plastic IP40 (6" x 6" x 48" aprox with shipping box)
* Data logging - 10,000 moisture measurements plus date, batch & temperature
* Operational Area:- Safe Area
   
  * In view of betterment, the product specification are subject to change without notice.
  .................................................................................................................................................................................................................
 
 

Oxygen Analyzer for Continuous Check…

   
 
Oxygen Analyzer  
   
  Oxygen analyzer uses HI Tech Sensor with user friendly operative feature for measuring oxygen concentration.

APPLICATIONS

* KEEP CONTROLING OXYGEN LEVEL IN AIR SEPERATION PLANTS.
* CHECKING CYLINDER GAS QUALITY.
* PHARMA & FOD INDUSTRIES.
* PURGE GAS MONITORING.

FEATURES

* Uses latest HI Tech sensor (Zirconia/Electrochemical).
* Supplied with sampling system.
* Measures up to 100 % for purity and also in PPM for Traces.
* Fast response time.

Ennovacion series oxygen analyser measures oxygen concentrations from percentage levels to a fractions of parts per million (ppm) in clean gases.

Packaged on a 19” rack mounting enclosure, it uses a zirconia oxygen sensor to provide accurate measurement with minimal interference from other gases. The unique cell and heater design gives very fast warm-up times, rapid response, and long sensor life. A wide choice of sampling options is provided to produce virtually ‘custom-built’ systems. A large multi-digit auto ranging LCD is used to display measured concentrations and the user adjustable parameters in configuration mode.

The standard sampling system is a simple needle valve and flow meter arrangement.
Standard options provide alternatives to cover a wide variety of applications.
MM Automation also supply a range of sample conditioning accessories to cater for most sample sources.
   
  SPECIFICATIONS
   
 
Display : Multi-digit LCD, character height 12.7mm
Range : 0.1ppm to 100% oxygen,(as per application)
Resolution : From 10% to 100%: 0.1% & .01% up to 9.99%.
From 0 to 5/50/500ppm: 0.01/0.1/01/10ppm
Accuracy : 100% to 100ppm: }2% of reading or better
99ppm to 10ppm: }1ppm
0.1ppm to 9/9ppm: }0.2ppm
Stability : Better than 2% of reading or 0.5ppm/month, whichever is greater
Sample flow : Between 100 and 300ml/min for optimum operation
Response : Iin clean inert atmospheres % levels- less than 02s for 90% change Levels from 500 to 100ppm: less than 15s for 90% change. For lesser ,its higher.
Sample : Inlet pressure 10mbar minimum/8bar maximum Temperature Ambient
Sampling : Extra As per application
Connection : located on back panel of unit. fitting suitable for 0.25inch/6mm outside diameter tube
Output : Standard : 4 to 20mA
Alarm outputs : 2 alarms: each user-configurable to OFF, HIGH or LOW status
Ambient temperature : 50 °C maximum
Power supply : Please specify option required from the following:
110/230V, 50 Hz at 80VA max
Mounting : 19” Rack-mounting enclosure 3U high and 270mm deep
     
  * In view of betterment, the product specification are subject to change without notice.
 
ENQUIRY
 
 
   
 

* Indicates Compulsory Fields
 

Name of Company : *
Name of Contact Person :*
Address / City / Location : *
Tel. No. / Cell No. : *
Email : *
Requirements Details : *
 
 
Home - About Us - Products - Enquiry - Contact Us