Home Products Profile Contact Enquiry  

 
 

Voltage Stabilizers

We are leading manufacturer of Relay Type A.C. step Voltage Stabilizers, Automatic Voltage Stabilizers, Servo Controlled Voltage Stabilizers. We also manufacture voltage stabilizer with different capacity/ input voltages (Extreme low wide input range) & having big production capacity.

Sr.
No.
Model Max.
KVA
Max.
Amp.
MCB
FUSE
Over/UnderV Trip Time Delay Input V Output Vat No Load V meter Applications
1
AR51 0.45
2
Fuse
NO-Basic-Direct

NO-Basic- Direct
175-275 200-250
NO
Upto 300 ltr Refrigerator.
2 ART51 0.45
2
Fuse Yes Yes-2 to 4 minutes 175-275 200-250
NO
Upto 300 ltr Refrigerator.
3 ARL51 0.4 1.5
Fuse NO-Basic-Direct NO-Basic- Direct 120-145-275 170-200-250
NO
Upto 300 ltr Refrigerator.Upto 1.5A
4 AD71 0.7
2.2
Fuse Yes Yes-2 to 4 minutes 155-275 200-250
NO
Upto 300 ltr Refrigerator.
5 AD71M 0.7
2.2
Fuse Yes Yes-2 to 4 minutes 155-275 200-250
Yes
Upto 300 ltr Refrigerator.
6 AD101 0.85
3
Fuse Yes Yes-2 to 4 minutes 155-275 200-250
NO
Upto 400 ltr Refrigerator.
7 AD101M 0.85
3
Fuse Yes Yes-2 to 4 minutes 155-275 200-250
Yes
Upto 400 ltr Refrigerator.
8 AD151 1.2
4.5
Fuse Yes Yes-2 to 4 minutes 155-275 200-250
NO
9 AD151M 1.2 4.5 Fuse Yes Yes-2 to 4 minutes 155-275 200-250 Yes Deep Freezer /Refrigerator.upto 4.5A

Output  : 200 to 250 +/- 3 V at no load  

 

[ AC MOTOR OPERATED VARIAC TYPE ]

1. INPUT V: 170 TO 270
2. OUTPUT V: 230+/-1%V
3. Reset: Auto.
4. Under Volt. trip: below 210v Output volts
5. Over volt trip: At above 250v Output volts.
6. Time delay: 10 to 15 seconds.
7. Voltmeter: At output Volt. side.
8. Overload & Short CKT protection :
With the help of MCB at input.
9. Set Volt: From Front panel
in the range of 225 to 235 Aprx.
10. LED Indication: Beyond input
acceptance voltage range.  

 

5.0 KVA, 10 KVA, 15.0 KVA, 20.0 KVA, 30.0 KVA & 50.0 KVA

Features
¤ Suitable for unbalance load & voltage ¤ Input voltage : 340 to 450 V br> ¤ Output V : 400 ± 1% V
¤ LED Indication : For each phase at our of input acceptance voltage
¤ Set Voltage : Facility for each phase in the range of ± 5 volts
¤ Overload & Short CKT Protection : provided with the help of 3 pole MCB
¤ Over / Under Voltage Trip Provided at output side
¤ Time Delay : 15 to 30 seconds for output supply to ON
¤ Voltmeter L with selector switch
¤ Reset : Auto
¤ Auto / Manual : with increase / decrease facility in manual mode in each phase
¤ Single phasing prevention : Provided
¤ Indication : Input ON, Output ON & on each phase Input out of acceptance voltage range
¤ AC Synchronous motor operated variac

Unbalance type 3 phase 4 wire system three independent controllers
Three Single phase voltage stabiliser system are connected in star position
Each phase will correct output supply voltage
 

Capacity max : 5.0 KVA / Upto max line current : 5.0 A  

Applications :
For Computer
Xerox Machine
Medical Equipments
Photo Stat Machine
Laboratories & Process Control Devices
Telecom Base station
Broadcasting Station
CNC Machine Etc.

Capacity max : 10.0 KVA / Upto max line current : 10.0 A
Capacity max : 15.0 KVA / Upto max line current : 15.0 A
Capacity max : 20.0 KVA / Upto max line current : 20.0 A
Capacity max : 25.0 KVA / Upto max line current : 25.0 A
Capacity max : 30.0 KVA / Upto max line current : 30.0 A
Capacity max : 50.0 KVA / Upto max line current : 50.0 A
 

Designed & Hosted by : MID  Promoted by : GID