2300
FAST mP BASED PROCESS INDICATOR / ALARM UNIT
Main features
* Pressure transmitter, force, strain-gauge, potentiometer,
transmitter inputs
* Fast response time (2msec)
* Automatic calibration checking for strain-gauge 6-wires
* 32 segment linearisation
* Peak, valley, peak-to-peak memory
* Serial line: configurable optoisolated 4-wires.
Protocol:
GEFRAN CENCAL or MODBUS
40 TB
TEMPERATURE AND PRESSURE
DOUBLE INDICATOR / ALARM UNIT
Main features
*
Inputs configurable from faceplate.
*
Easy strain-gauge calibration with sensitivity auto-ranging.
* Control of sensor power supply (input 1).
*
Selectable code protection.
*
Possibility to configure the unit.
*
Power supply for transmitters.
* Easy to configure . Custom
linearization available.
*
Engineering units of the most common physical quantities
available either on display or on labels.
*
Acquisition and alarm programmable from 15 up to 120 msec.
with resolution from 16000 to 4000 divisions
*
Retransmission of variable values
*
3 alarms completely configurable from faceplate.
* 4-wire, configurable serial line.
Protocol:
GEFRAN CENCAL or MODBUS
2308
MULTIZONE INDICATOR / ALARM UNIT
Main features
* Up to 8 displayed points with manual or automatic scanning
* Thermocouple, resistance thermometer,
DC V/I, AC V/I, potentiometer inputs
* Heterogeneous inputs
* Up to 10 freely configurable alarm points
* Optoisolated 4-wires digital communication. Protocol:
GEFRAN CENCAL or MODBUS
40T 48 / 40T 96
CONFIGURABLE INDICATORS - ALARM UNITS
Main features
* Faceplate configurable input
*
Protected by a personal code
*
Configurable by a serial link
*
Transmitter power supply incorporated
*
Custom thermocouple linearisation available
* Internal linearisation for engineering
units
*
Labels provided for the more common physical units
*
Sampling time and trip intervention programmable between
15 and 120msec with resolution between 2000 and 8000 steps
*
Retransmission of the measured variable signal l 3 trip points,
completely configurable from the faceplate
40B 48 / 40B 96
AC CURRENT / VOLTAGE CONFIGURABLE INDICATOR - ALARM UNITS
Main features
* Strain-gauge or potentiometer input -configurable by faceplate
* Sensor supply check
* Easy to calibrate with sensitivity auto-ranging
*
Protected by a personal code
*
Configurable by serial link
*
Internal linearisation for engineering units
*
Labels provided for the more common physical units
*
Sampling time and trip intervention programmable between
15 and 120msec with resolution between 2000 and 8000 steps
* Retransmission of the measured
variable signal l 3 trip points, completely configurable
from the faceplate |